The use effectiveness of the Copper T-200 in Matlab, Bangladesh
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Rob, U. | - |
dc.contributor.author | Phillips, J.F. | - |
dc.contributor.author | Chakraborty, J. | - |
dc.contributor.author | Koenig, M.A. | - |
dc.date.accessioned | 2012-12-23T06:51:09Z | - |
dc.date.available | 2012-12-23T06:51:09Z | - |
dc.date.issued | 1987 | - |
dc.identifier.citation | Int J Gynaecol Obstet 1987 Aug;25(4):315-22 | en |
dc.identifier.uri | http://hdl.handle.net/123456789/4330 | - |
dc.description.abstract | Using a unique record keeping system, the use effectiveness of the Copper T-200 is examined in rural Bangladesh. In Matlab the Copper T-200 is a highly effective contraceptive modality. The adopters are typically low to medium parity women under 30 years of age. The most important cause of termination among women in the study was voluntary removal of the device. The complaint most often reported was bleeding followed by pain and weakness. The Matlab experience suggests that sustained motivation and regular resupply are the two key components of this highly successful family planning program. PIP: The Copper T-200 is an intrauterine contraceptive device made of polythelene, shaped like the letter T with a 200 mm copper wire wound around the vertical stem. Using a unique record keeping system, the use effectiveness of the Copper T-200 is examined in rural Bangladesh. The adopters are typically low to medium parity women under 30 years of age. The most important cause of termination among women in the study was voluntary removal of the device. The complaint most often reported was bleeding followed by pain and weakness. The Copper T is a highly effective contraceptive modality in Matlab, with use effectiveness that compares favorably with IUD rates observed elsewhere and efficacy that is superior to rates typically observed for methods such as pills and condoms--methods which require sustained motivation and regular resupply. The Matlab findings indicate, however, that Copper T adoption does not obviate the need for regular attention to users. The Matlab experience suggests that sustained motivation and regular resupply are the 2 key components of this highly successful family planning program | en |
dc.format.extent | 404792 bytes | - |
dc.format.mimetype | application/pdf | - |
dc.language.iso | en | en |
dc.subject | Allied Health Personnel | en |
dc.subject | Evaluation Studies as Topic | en |
dc.subject | Intrauterine Device Expulsion | en |
dc.subject | Intrauterine Devices, Copper | en |
dc.subject | Patient Dropouts | en |
dc.subject | Pregnancy | en |
dc.subject | Probability | en |
dc.subject | Bangladesh | en |
dc.title | The use effectiveness of the Copper T-200 in Matlab, Bangladesh | en |
dc.type | Article | en |
Appears in Collections: | A. Original papers |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
1987-IntJGynaecolObstet-315-RobU.pdf | 395.3 kB | Adobe PDF | View/Open Request a copy |
This item is protected by original copyright |